Search results for " keratoplasty."
showing 7 items of 7 documents
Comparison of DMEK and DSAEK in Eyes With Endothelial Decompensation After Previous Penetrating Keratoplasty.
2021
PURPOSE Posterior lamellar keratoplasty is increasingly applied in patients with endothelial decompensation after penetrating keratoplasty (PK). The aim of this study was to compare the results of Descemet membrane endothelial keratoplasty (DMEK) and Descemet stripping automated endothelial keratoplasty (DSAEK) after PK. METHODS In this retrospective study, clinical data of 30 patients who received DMEK (n = 19) or DSAEK (n = 11) for endothelial decompensation after PK were evaluated. All lamellar keratoplasties were performed at the Department of Ophthalmology at University Hospital Mainz, Germany. Primary end point included best-corrected visual acuity, and secondary end points included e…
Corneal aberrations pre and post-application of new contact lens in the astigmatism after penetrating keratoplasty.
2007
Irregularity of the posterior corneal surface after curved interface femtosecond laser-assisted versus microkeratome-assisted descemet stripping auto…
2013
During donor tissue preparation for Descemet stripping automated endothelial keratoplasty (DSAEK), either microkeratome or femtosecond laser can be used for intrastromal cutting. We compared morphological and functional outcomes after DSAEK using both cutting techniques.In this retrospective study, 22 uneventful DSAEK surgeries were reviewed. Eight donor corneas were prepared for DSAEK using the VisuMax femtosecond laser (Carl Zeiss Meditec AG, Jena, Germany). Fourteen corneas were processed using an Amadeus II microkeratome (Ziemer Ophthalmic Systems AG, Port, Switzerland). The postoperative best spectacle-corrected visual acuity was measured. Furthermore, corneal optical coherence tomogra…
Favorable outcome in open globe injuries with low OTS score
2014
Purpose:.Open globe eye injuries can have profound social and economic consequences. Here, we describe two cases of war and outdoor activity open globe eye injury where, despite a low OTS score,.current microsurgical technology allowed for a favorable outcome.Case report 1: A 33-year-old Libyan soldier had been treated for an open-globe grenade blast trauma to his left eye, which showed light perception and OTS score 2..He had undergone a lensectomy and PPV with silicone oil tamponade. Surgical treatment included scleral buckling,.cornea trephination, tem-porary Eckardt keratoprosthesis, PPV revision, intraocular lens (IOL) implantation, and corneal grafting. Six months later, his VA was im…
Irregularity of the posterior corneal surface during applanation using a curved femtosecond laser interface and microkeratome cutting head.
2012
PURPOSE: To evaluate the irregularity of the posterior corneal surface and intrastromal dissection during the preparation of donor tissue for Descemet stripping automated endothelial keratoplasty (DSAEK) using a curved interface femtosecond laser and microkeratome. METHODS: Sixteen human donor corneas unsuitable for transplantation were divided into two groups: a femtosecond (FS) laser group (n=7) using the VisuMax femtosecond laser (Carl Zeiss Meditec) and a microkeratome group (n=9) using the Amadeus II microkeratome (Ziemer Ophthalmic Group). The corneas were fixed on artificial anterior chambers. Horizontal cross-sections were obtained using spectral-domain optical coherence tomography…
Bilateral Ultrathin Descemet’s Stripping Automated Endothelial Keratoplasty vs. Bilateral Penetrating Keratoplasty in Fuchs’ Dystrophy: Corneal Highe…
2021
Background and Objectives: The objective of this paper is to compare the visual outcomes and quality of life (QoL) after bilateral ultrathin Descemet’s stripping automated endothelial keratoplasty (UT-DSAEK) with bilateral penetrating keratoplasty (PK) for Fuchs’ endothelial dystrophy (FED). Materials and Methods: Retrospective comparative cohort study, including 11 patients with FED who underwent bilateral PK and 13 patients with FED who underwent bilateral UT-DSAEK. All patients were already pseudophakic or had undergone a combined cataract procedure. The main outcomes were corrected distance visual acuity (CDVA) corneal higher-order aberrations (HOAs), contrast sensitivity (CS) and quali…
Optical quality of hyperopic and myopic phakic intraocular lenses
2013
Aims: To assess and compare the optical quality of the myopic and hyperopic implantable collamer lens (ICL) from its wavefront aberrations for different powers and pupil diameters. Settings and Design: Prospective study. Material and Methods: The wavefront aberrations of two myopic (−3 and −6 diopters (D)) and two hyperopic V4b ICLs (+3 and +6D) were measured in vitro . To assess and compare the optical quality of different powers of ICLs, we analyzed the root mean square (RMS) of total higher order aberrations (HOAs), trefoil, coma, tetrafoil, secondary astigmatism, and spherical aberration at 3- and 4.5-mm pupil. In addition, the point spread functions (PSFs) of each ICL evaluated were ca…